Related papers: Test Stand Measurements for an ILC Polarimeter
A central property of Chern insulators is the robustness of the topological phase and edge states to impurities in the system. Despite this, Chern number cannot be straightforwardly calculated in the presence of disorder. Recently, work has…
The International Linear Collider has a rich physics programme, whatever lies beyond the standard model. Accurate measurement of the top quark mass is needed to constrain the model or its extensions. If there is a light Higgs boson the LHC…
Possible instrumental set--ups for the measurement of CMB polarization are reviewed in this article. We discuss existing and planned instruments, putting special emphasis on observational, instrumental, and data processing issues for the…
State-of-the-art polarimeter calibration is reviewed. Producing many quasi-random polarization states and moving/bending a fiber without changing power allows finding a polarimeter calibration where the degree-of-polarization reaches unity…
The Particle Flow Analysis approach retained for the future ILC detectors requires high granularity and compact particle energy deposition. A Glass Resistive Plate Chamber based Semi-Digital calorimeter can offer both at a low price for the…
We first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of…
A position sensitive Cherenkov detector was built, consisting of 64 SiPMs with an active area of 3x3 mm^2 and a pixel size of 100x100 \mu m^2. The sensitive area is increased by a light concentrator which consists of 64 pyramid-shaped…
Precision measurement of the stop mass at the ILC is done in a method based on cross-sections measurements at two different center-of-mass energies. This allows to minimize both the statistical and systematic errors. In the framework of the…
The POLISH2 optical polarimeter has been in operation at the Lick Observatory 3-m Shane telescope since 2011, and it was commissioned at the Gemini North 8-m in 2016. This instrument primarily targets exoplanets, asteroids, and the Crab…
The lithium chloride aqueous solution has great potential to be the detection medium of a novel solar neutrino detector. The nuclide \ce{^7 Li} provides a charged-current interaction channel with a high cross-section for the MeV-scale solar…
This paper presents the study on the characterization of glass electrodes, which are one of the main components of detectors like Resistive Plate Chambers (RPCs). The RPCs are being used in various ongoing High Energy Physics experiments,…
The public collider phenomenology computing tool CheckMATE (Check Models at Terascale Energies) was originally designed to allow theorists to quickly test their favourite BSM models against various existing LHC analyses performed by ATLAS…
The International Linear Collider (ILC) will be able to precisely measure the electroweak couplings of the top in e+e- -> tt~. We compare the limits which can be achieved at the ILC with those which can be obtained in tt~gamma$ and tt~Z…
In the recent times, test of Lorentz Invariance has been used as a means to probe theories of physics beyond the standard model. We describe a simple way of utilizing the polarimeters, which are a critical beam instrument at precision and…
The 4th detector is rich in particle identification measurements from the dual-readout calorimeters, the cluster-timing tracking chamber, the muon spectrometer, and combinations of these systems. In all, a total of 13 measurements…
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve…
This note summarizes the results of the "Workshop on Polarisation and Beam Energy Measurements at the ILC", held at DESY (Zeuthen) April 9-11 2008. The topics for the workshop included (i) physics requirements, (ii) polarised sources and…
We study phenomenological consequences of a noncommutative extension of the standard model in the theta-expanded approach at the ILC. We estimate the sensitivity of the ILC for the noncommutative scale Lambda_NC. Comparing with earlier…
The pair monitor is a beam profile monitor at interaction point (IP) for the international linear collider (ILC). We have designed and developed the pair monitor as a silicon pixel sensor which is located at about 400 cm from IP. As the…
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…