Thermal fluctuation of the cantilever position sets a fundamental limit for the precision of any Scanning Force Microscope. In the present work we analyse how these fluctuations limit the determination of the resonance frequency of the…

Mesoscale and Nanoscale Physics · Physics 2010-03-03 J. Colchero , M. Cuenca , J. F. Gonzalez Martinez , J. Abad , E. Palacios-Lidon , J. Abellan

A Faraday force magnetometer is presented for measurements of magnetization at temperatures down to 100~mK and in magnetic fields up to 14~T. The specimen is mounted on a flexible cantilever forming a force-sensing capacitor in combination…

Materials Science · Physics 2020-07-22 Dominic Blosser , Leonardo Facheris , Andrey Zheludev

Atomic force microscopy cantilevers are often, intentionally or not, heated at their extremity. We describe a model to compute the resulting temperature field in the cantilever and in the surrounding fluid on a wide temperature range. In…

Statistical Mechanics · Physics 2021-10-08 Basile Pottier , Ludovic Bellon

Quantitative thermal imaging has the potential of reliable temperature measurement across an entire field-of-view. This non-invasive technique has applications in aerospace, manufacturing and process control. However, robust temperature…

Instrumentation and Detectors · Physics 2022-04-27 Jamie McMillan , Aaron Whittam , Maciej Rokosz , Rob Simpson

This paper presents a novel method for estimating the temperature of magnetic nanoparticles (MNPs) based on AC magnetization harmonics of MNPs dominated by Brownian relaxation. The difference in the AC magnetization response and…

Temperature of a finite-sized system fluctuates due to the thermal fluctuations. However, a systematic mathematical framework for measuring or estimating the temperature is still underdeveloped. Here, we incorporate the estimation theory in…

Statistical Mechanics · Physics 2026-03-17 Shaoyong Zhang , Zhaoyu Fei , Xiaoguang Wang

The influence of the environment in the thermal equilibrium properties of a bipartite continuous variable quantum system is studied. The problem is treated within a system-plus-reservoir approach. The considered model reproduces the…

Quantum Physics · Physics 2011-07-05 D. M. Valente , A. O. Caldeira

We present a parallel network of 16 demagnetization refrigerators mounted on a cryofree dilution refrigerator aimed to cool nanoelectronic devices to sub-millikelvin temperatures. To measure the refrigerator temperature, the thermal motion…

Instrumentation and Detectors · Physics 2017-10-16 Mario Palma , Dario Maradan , Lucas Casparis , Tai-Min Liu , Florian Froning , Dominik M. Zumbühl

The measurement of thermal fluctuations provides information about the microscopic state of a thermodynamic system and can be used in order to extract work from a single heat bath in a suitable cyclic process. We present a minimal framework…

Statistical Mechanics · Physics 2015-06-03 Léo Granger , Holger Kantz

We introduce a primary thermometer which measures the temperature of a Bose-Einstein Condensate in the sub-nK regime. We show, using quantum Fisher information, that the precision of our technique improves the state-of-the-art in…

Quantum Physics · Physics 2014-09-23 Carlos Sabín , Angela White , Lucia Hackermuller , Ivette Fuentes

We study the most suitable procedure to measure the effective temperature in off-equilibrium systems. We analyze the stationary current established between an off-equilibrium system and a thermometer and the necessary conditions for that…

Disordered Systems and Neural Networks · Physics 2015-06-24 Adan Garriga , Felix Ritort

The meaning of temperature in nonequilibrium thermodynamics is considered by using a forced harmonic oscillator in a heat bath, where we have two effective temperatures for the position and the momentum, respectively. We invent a concrete…

Statistical Mechanics · Physics 2007-05-23 Takahiro Hatano , David Jou

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…

Instrumentation and Detectors · Physics 2025-08-28 D. P. Kapasi , T. G. McRae , J. Eichholz , P. A. Altin , D. E. McClelland , B. J. J. Slagmolen

Thermometry is essential for studying many-body physics with ultracold atoms. Accurately measuring low temperatures in these systems, however, remains a significant challenge due to the absence of a universal thermometer. Most widely…

Planar, double-torsional oscillators are especially suitable for short-range macroscopic force search experiments, since they can be operated at the limit of instrumental thermal noise. As a study of this limit, we report a measurement of…

Statistical Mechanics · Physics 2014-10-27 H. Yan , E. A. Housworth , H. O. Meyer , G. Visser , E. Weisman , J. C. Long

We cool the fundamental mechanical mode of an ultrasoft silicon cantilever from a base temperature of 2.2 K to 2.9 +/- 0.3 mK using active optomechanical feedback. The lowest observed mode temperature is consistent with limits determined by…

Other Condensed Matter · Physics 2007-07-04 M. Poggio , C. L. Degen , H. J. Mamin , D. Rugar

We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and…

Instrumentation and Detectors · Physics 2022-11-10 S. M. Fleischer , M. P. Ross , K. Venkateswara , C. A. Hagedorn , E. A. Shaw , E. Swanson , B. R. Heckel , J. H. Gundlach

We report an accurate measurement of the phase noise of a thermally limited electronic oscillator at 300 K. By thermally limited we mean that the white signal-to-noise ratio of the oscillator is at or near the level generated by the thermal…

Instrumentation and Detectors · Physics 2017-01-13 Archita Hati , Craig W. Nelson , David Pappas , David A. Howe

Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that…

Mesoscale and Nanoscale Physics · Physics 2018-01-10 Corinne E. Isaac , Elizabeth A. Curley , Pamela T. Nasr , Hoang L. Nguyen , John A. Marohn

We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the…

Instrumentation and Detectors · Physics 2020-11-16 J. Wheeler , M. R. Vissers , M. Malnou , J. Hubmayr , J. N. Ullom , J. Gao