English
Related papers

Related papers: Preparation of Neutron-activated Xenon for Liquid …

200 papers

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $\gamma$ interactions from…

A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly…

Instrumentation and Methods for Astrophysics · Physics 2010-07-23 A. Manalaysay , T. Marrodan Undagoitia , A. Askin , L. Baudis , A. Behrens , A. D. Ferella , A. Kish , O. Lebeda , R. Santorelli , D. Venos , A. Vollhardt

Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe…

Instrumentation and Detectors · Physics 2017-10-04 I. Israelashvili , A. E. C. Coimbra , D. Vartsky , L. Arazi , S. Shchemelinin , E. N. Caspi , A. Breskin

Dual-phase liquid xenon (LXe) detectors lead the direct search for particle dark matter. Understanding the signal production process of nuclear recoils in LXe is essential for the interpretation of LXe based dark matter searches. Up to now,…

Instrumentation and Detectors · Physics 2018-12-12 Elena Aprile , Matthew Anthony , Qing Lin , Zach Greene , Patrick de Perio , Fei Gao , Joseph Howlett , Guillaume Plante , Yun Zhang , Tianyu Zhu

We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid…

Instrumentation and Detectors · Physics 2009-12-11 L. W. Kastens , S. B. Cahn , A. Manzur , D. N. McKinsey

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…

Instrumentation and Detectors · Physics 2022-10-20 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but…

High Energy Physics - Experiment · Physics 2026-04-24 D. S. Akerib , A. K. Al Musalhi , F. Alder , B. J. Almquist , C. S. Amarasinghe , A. Ames , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , A. Baker , S. Balashov , J. Bang , J. W. Bargemann , E. E. Barillier , K. Beattie , A. Bhatti , T. P. Biesiadzinski , H. J. Birch , E. Bishop , G. M. Blockinger , C. A. J. Brew , P. Brás , S. Burdin , M. C. Carmona-Benitez , M. Carter , A. Chawla , H. Chen , Y. T. Chin , N. I. Chott , S. Contreras , M. V. Converse , R. Coronel , A. Cottle , G. Cox , D. Curran , C. E. Dahl , I. Darlington , S. Dave , A. David , J. Delgaudio , S. Dey , L. de Viveiros , L. Di Felice , C. Ding , J. E. Y. Dobson , E. Druszkiewicz , S. Dubey , C. L. Dunbar , S. R. Eriksen , N. M. Fearon , N. Fieldhouse , S. Fiorucci , H. Flaecher , E. D. Fraser , T. M. A. Fruth , P. W. Gaemers , R. J. Gaitskell , A. Geffre , J. Genovesi , C. Ghag , J. Ghamsari , A. Ghosh , S. Ghosh , R. Gibbons , S. Gokhale , J. Green , M. G. D. van der Grinten , J. J. Haiston , C. R. Hall , T. Hall , R. H Hampp , S. J. Haselschwardt , M. A. Hernandez , S. A. Hertel , G. J. Homenides , M. Horn , D. Q. Huang , D. Hunt , E. Jacquet , R. S. James , K. Jenkins , A. C. Kaboth , A. C. Kamaha , M. K. Kannichankandy , D. Khaitan , A. Khazov , J. Kim , Y. D. Kim , D. Kodroff , E. V. Korolkova , H. Kraus , S. Kravitz , L. Kreczko , V. A. Kudryavtsev , C. Lawes , E. B. Leon , D. S. Leonard , K. T. Lesko , C. Levy , J. Lin , A. Lindote , W. H. Lippincott , J. Long , M. I. Lopes , W. Lorenzon , C. Lu , S. Luitz , W. Ma , V. Mahajan , P. A. Majewski , A. Manalaysay , R. L. Mannino , R. J. Matheson , C. Maupin , M. E. McCarthy , D. N. McKinsey , J. McLaughlin , J. B. McLaughlin , R. McMonigle , B. Mitra , E. Mizrachi , M. E. Monzani , K. Morå , E. Morrison , B. J. Mount , M. Murdy , A. St. J. Murphy , H. N. Nelson , F. Neves , A. Nguyen , C. L. O'Brien , F. H. O'Shea , I. Olcina , K. C. Oliver-Mallory , J. Orpwood , K. Y Oyulmaz , K. J. Palladino , N. J. Pannifer , S. J. Patton , B. Penning , G. Pereira , E. Perry , T. Pershing , A. Piepke , S. S. Poudel , Y. Qie , J. Reichenbacher , C. A. Rhyne , G. R. C. Rischbieter , E. Ritchey , H. S. Riyat , R. Rosero , N. J. Rowe , T. Rushton , D. Rynders , S. Saltão , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , G. Sehr , B. Shafer , S. Shaw , W. Sherman , K. Shi , T. Shutt , C. Silva , G. Sinev , J. Siniscalco , A. M. Slivar , A. M. Softley-Brown , V. N. Solovov , P. Sorensen , J. Soria , T. J. Sumner , A. Swain , M. Szydagis , D. R. Tiedt , D. R. Tovey , J. Tranter , M. Trask , K. Trengove , M. Tripathi , A. Usón , A. C. Vaitkus , O. Valentino , V. Velan , A. Wang , J. J. Wang , Y. Wang , L. Weeldreyer , T. J. Whitis , K. Wild , M. Williams , J. Winnicki , L. Wolf , F. L. H. Wolfs , S. Woodford , D. Woodward , C. J. Wright , Q. Xia , J. Xu , Y. Xu , M. Yeh , D. Yeum , J. Young , W. Zha , H. Zhang , T. Zhang , Y. Zhou

The R&D for a new type of liquid xenon (LXe) detector is ongoing to search for the neutrinoless double-beta decay ($0\nu2\beta$). As a result of the KamLAND-Zen experiment, it is very important to realize the all active region detector for…

Instrumentation and Detectors · Physics 2020-05-20 Kota Ueshima

Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency.…

Instrumentation and Detectors · Physics 2008-11-26 K. Ni , E. Aprile , K. L. Giboni , P. Majewski , M. Yamashita

We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon…

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation…

Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear…

Astrophysics · Physics 2009-11-10 E. Aprile , K. L. Giboni , P. Majewski , K. Ni , M. Yamashita , R. Hasty , A. Manzur , D. N. McKinsey

Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier…

Instrumentation and Detectors · Physics 2015-06-23 I. Israelashvili , M. Cortesi , D. Vartsky , L. Arazi , D. Bar , E. N. Caspi , A. Breskin

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…

Instrumentation and Detectors · Physics 2022-02-23 N. Ackerman , J. Albert , M. Auger , D. J. Auty , I. Badhrees , P. S. Barbeau , L. Bartoszek , E. Baussan , V. Belov , C. Benitez-Medina , T. Bhatta , M. Breidenbach , T. Brunner , G. F. Cao , W. R. Cen , C. Chambers , B. Cleveland , R. Conley , S. Cook , M. Coon , W. Craddock , A. Craycraft , W. Cree , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , C. G. Davis , J. Davis , S. Delaquis , A. Der Mesrobian-Kabakian , R. deVoe , T. Didberidze , J. Dilling , A. Dobi , A. G. Dolgolenko , M. J. Dolinski , M. Dunford , J. Echevers , L. Espic , W. Fairbank , D. Fairbank , J. Farine , W. Feldmeier , S. Feyzbakhsh , P. Fierlinger , K. Fouts , D. Franco , D. Freytag , D. Fudenberg , P. Gautam , G. Giroux , R. Gornea , K. Graham , G. Gratta , C. Hagemann , C. Hall , K. Hall , G. Haller , E. V. Hansen , C. Hargrove , R. Herbst , S. Herrin , J. Hodgson , M. Hughes , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , A. Johnson , T. N. Johnson , S. Johnston , A. Karelin , L. J. Kaufman , R. Killick , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , F. Leonard , F. LePort , G. S. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , D. Mackay , R. MacLellan , M. Marino , J. -M. Martin , Y. Martin , T. McElroy , K. McFarlane , T. Michel , B. Mong , D. C. Moore , K. Murray , R. Neilson , O. Njoya , O. Nusair , K. O'Sullivan , A. Odian , I. Ostrovskiy , C. Ouellet , A. Piepke , A. Pocar , C. Y. Prescott , K. Pushkin , F. Retiere , A. Rivas , A. L. Robinson , E. Rollin , P. C. Rowson , M. P. Rozo , J. Runge , J. J. Russell , S. Schmidt , A. Schubert , D. Sinclair , K. Skarpaas , S. Slutsky , E. Smith , A. K. Soma , V. Stekhanov , V. Strickland , M. Swift , M. Tarka , J. Todd , T. Tolba , D. Tosi , T. I. Totev , R. Tsang , K. Twelker , B. Veenstra , V. Veeraraghavan , J. -L. Vuilleumier , J. -M. Vuilleumier , M. Wagenpfeil , A. Waite , J. Walton , T. Walton , K. Wamba , J. Watkins , M. Weber , L. J. Wen , U. Wichoski , M. Wittgen , J. Wodin , J. Wood , G. Wrede , S. X. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Ya Zeldovich , T. Ziegler

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the…

A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by…

Astrophysics · Physics 2007-07-30 E. Aprile , K. L. Giboni , P. Majewski , K. Ni , M. Yamashita

Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The…

Instrumentation and Detectors · Physics 2010-04-06 A. Manzur , A. Curioni , L. Kastens , D. N. McKinsey , K. Ni , T. Wongjirad

NEXT-DEMO is a 1:4.5 scale prototype of the NEXT100 detector, a high-pressure xenon gas TPC that will search for the neutrinoless double beta decay of $^{136}$Xe. X-ray energy depositions produced by the de-excitation of Xenon atoms after…

Instrumentation and Detectors · Physics 2019-08-13 L. Serra , D. Lorca , J. Martin-Albo , M. Sorel , J. J. Gomez-Cadenas

An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…

‹ Prev 1 2 3 10 Next ›