Related papers: Investigations of a THGEM-based imaging detector
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric…
In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive…
The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…
An interpolating two-dimensional X-ray imaging detector based on a single photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research…
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…
This paper presents an investigation of the discharge propagation (DP) to the readout electrode that occurs with a microsecond time delay after a primary discharge that develops inside a GEM foil hole. A single hole THGEM (THick GEM) foil…
The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron…
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a…
A novel concept is proposed for large-volume single-phase noble-liquid TPC detectors for rare events. Both radiation-induced scintillation-light and ionization-charge are detected by Liquid Hole-Multipliers, LHM, immersed in the noble…
Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could…
Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…
Gas Electron Multiplier (GEM) is one of the devices for gas amplification and available as an amplification part of detectors for many experiments. A GEM with a 50 $\mu m$ thick insulator is popular and widely used in many experimental…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated…
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would…
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…
A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…