Related papers: Development of Tracking Detectors with industriall…
In 2009, the RHIC spin physics program completed the first data taking period of polarized $\vec{p}+\vec{p}$ collisions at $\sqrt{s} = 500$ GeV, accumulating ~12 pb$^{-1}$ with ~39% beam polarization. This opens a new era in the study of…
The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime…
A large volume time projection chamber (TPC) has been proposed as main tracking device for a detector at a future linear e+e- collider. Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment…
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed…
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…
In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the…
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of…
MAGIX is a planned experiment that will be implemented at the upcoming accelerator MESA in Mainz. Due to its location in the energy-recovering lane of the accelerator beam-currents up to 1mA with a maximum energy of 105 MeV will be…
Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected to reach ~1 MHz/cm2 for central Au-Au collisions at 8 AGeV.…
A new thermal neutron detector with the domestically produced THGEM (THick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was…
Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the…
A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by…
Non destructive quality control of microstructures at the manufacturing stage is an important issue in the foreseen use of huge numbers of such gaseous detectors in the future high luminosity colliders. In this work we report on the use of…
A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the…