English
Related papers

Related papers: Development of a 5 MHz frequency difference pre-mu…

200 papers

This paper reports main results of the phase noise comparison that has been performed between october 2005 and december 2006, using two oscillators at 5 and 100 MHz and un DRO at 3.5 GHz. The problem is not to compare the performances of…

High-stability quartz oscillators are needed in a number of space applications. A short-term stability of parts in 10^{-14} [Allan deviation \sigma y(\tau) ] is sometimes required, for integration time \tau of approximately 1-10 s. The…

Instrumentation and Detectors · Physics 2007-06-14 Fabrice Sthal , Xavier Vacheret , Patrice Salzenstein , Serge Galliou , Gilles Cibiel , Enrico Rubiola

This article deals with the erratic and inconsistent phase-noise spectra often seen in low-noise oscillators, whose floor is of the order of $-180$ dBc/Hz or less. Such oscillators are generally measured with two-channel instruments based…

Instrumentation and Detectors · Physics 2021-01-28 Yannick Gruson , Adrian Rus , Ulrich L. Rohde , Alexander Roth , Enrico Rubiola

Advances in power electronics have made it possible to achieve high power levels, e.g., reaching GW in grids, or alternatively high output bandwidths, e.g., beyond MHz in communication. Achieving both simultaneously, however, remains…

Signal Processing · Electrical Eng. & Systems 2023-09-13 Jinshui Zhang , Boshuo Wang , Xiaoyang Tian , Angel Peterchev , Stefan Goetz

Analog electrical elements such as mixers, filters, transfer oscillators, isolating buffers, dividers, and even transmission lines contribute technical noise and unwanted environmental coupling in time and frequency measurements. Software…

Instrumentation and Detectors · Physics 2016-08-06 Jeff A. Sherman , Robert Jördens

In multi-qubit superconducting systems utilizing flip-chip technology, achieving high accuracy in resonator frequencies is of paramount importance, particularly when multiple resonators share a common Purcell filter with restricted…

Quantum Physics · Physics 2023-12-12 Yuan Li , Tianhui Wang , Jingjing Hu , Dengfeng Li , Shuoming An

We report on the development and phase noise performance of a 9.1926 GHz microwave frequency synthesizer to be used as the local oscillator for a Cs fountain clock. It is based on frequency multiplication and synthesis from an ultralow…

Atomic Physics · Physics 2022-04-19 Wenbing Li , Yuanbo Du , Hui Li , Zehuang Lu

The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology.…

Instrumentation and Detectors · Physics 2013-02-05 John G. Hartnett , Stephen R. Parker , Eugene N. Ivanov , Travis Povey , Nitin R. Nand , Jean-Michel le Floch

We report on an electrical detection method of ultrasensitive carbon nanotube mechanical resonators. The noise floor of the detection method is reduced using a RLC resonator and an amplifier based on a high electron mobility transistor…

Mesoscale and Nanoscale Physics · Physics 2018-09-14 Jil Schwender , Ioannis Tsioutsios , Alexandros Tavernarakis , Quan Dong , Yong Jin , Urs Staufer , Adrian Bachtold

We demonstrate a double optical frequency reference (1529 nm and 1560 nm) for the telecom C-band using $^{87}$Rb modulation transfer spectroscopy. The two reference frequencies are defined by the 5S$_{1/2} F=2 \rightarrow $ 5P$_{3/2} F'=3$…

In this letter we report on an all optical-fibre approach to the synthesis of ultra-low noise microwave signals by photodetection of femtosecond laser pulses. We use a cascade of Mach-Zehnder fibre interferometers to realize stable and…

Optics · Physics 2015-05-28 A. Haboucha , W. Zhang , T. Li , M Lours , A. N. Luiten , Y. Le Coq , G. Santarelli

The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency…

Instrumentation and Detectors · Physics 2012-11-30 John G. Hartnett , Travis Povey , Stephen Parker , Eugene Ivanov

We describe the design of a low-phase-modulated (PM) noise, 40 GHz oscillator that uses a conventional air-dielectric cavity resonator as a frequency discriminator to improve the PM noise of a commercial 10 GHz dielectric resonator…

Instrumentation and Detectors · Physics 2014-04-21 Archita Hati , Craig W. Nelson , B. Riddle , David A. Howe

Coherent frequency division of high-stability optical sources permits the extraction of microwave signals with ultra-low phase noise, enabling their application to systems with stringent timing precision. To date, the highest performance…

Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100…

Instrumentation and Detectors · Physics 2012-05-15 Nitin R. Nand , John G. Hartnett , Eugene N. Ivanov , Giorgio Santarelli

We demonstrate experimentally a scheme to measure small temporal delays, much smaller than the pulse width, between optical pulses. Specifically, we observe an interference effect, based on the concepts of quantum weak measurements and weak…

We stabilise a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fibre-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb we measure independently the instability of…

Atomic Physics · Physics 2008-09-15 B. Lipphardt , G. Grosche , U. Sterr , Chr. Tamm , S. Weyers , H. Schnatz

The Allan variance of signal and reference frequencies is measured by a least-squares fit of the output of two analog-to-digital converters (ADC's) to ideal sine waves. The difference in the fit phase of the two channels generates the…

Instrumentation and Detectors · Physics 2018-03-14 Ralph G. DeVoe

This article analyzes the design of a low-noise amplifier intended as the input front-end for the measurement of the low-frequency components (below 10 Hz) of a 50 Ohm source. Low residual flicker is the main desired performance. This…

Instrumentation and Detectors · Physics 2009-11-11 Enrico Rubiola , Franck Lardet-Vieudrin

In contrast to the well-known phenomenon of frequency stabilization in a synchronized noisy nonlinear oscillator, little is known about its amplitude stability. In this paper, we investigate experimentally and theoretically the amplitude…

Applied Physics · Physics 2022-05-18 Martial Defoort , Sébastien Hentz , Steven W. Shaw , Oriel Shoshani
‹ Prev 1 2 3 10 Next ›