Related papers: Sensitivity of double resonance alignment magnetom…
Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a…
Optically pumped magnetometers are ultra-sensitive devices, but this sensitivity can significantly degrade due to heading errors, whereby a change in the angle between the pumping laser and the magnetic field translates to a change in the…
A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding $1\khz$. Pump and probe are…
An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 $\mu T$ field. Nuclear spins are manipulated either by $\pi/2$ pulses or by…
We have studied the noise spectra in a nonlinear magneto-optical rotation experiment in a rubidium vapor. We observed the reduction of noise in the intensity difference of two orthogonally polarized components of the laser beam. The…
Optical frequency stabilization is a critical component for precision scientific systems including quantum sensing, precision metrology, and atomic timekeeping. Ultra-high quality factor photonic integrated optical resonators are a prime…
In the optical pumping systems based on the pump-probe arrangement, the spin polarization of the atoms is generally monitored utilizing the probe laser beam, in which way an extra perturbation must be introduced and thus affects the normal…
Alkali-metal atomic magnetometry is widely used due to its high sensitivity and cryogen-free operation. However, when operating in geomagnetic field, it suffers from heading errors originating from nonlinear Zeeman (NLZ) splittings and…
We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…
Femtosecond magneto-optical pump-probe measurements of ultrafast demagnetization show an intriguing difference in the first 100 fs of the magneto-optical Kerr response depending on whether the polarization of the pump and probe beams are in…
The detection of environmental magnetic fields is well established by optically pumped atomic magnetometers. Another focus of magnetometry can be the research on magnetic or spin-active solid-state samples. Here we introduce a simple and…
Critically coupled resonant optical cavities are often used as mode cleaners in optical systems to improve the signal to noise ratio (SNR) of a signal that is encoded as an amplitude modulation of a laser beam. Achieving the best SNR…
The operation of polarimetric based single beam three axis atomic magnetometer is studied. The magnetometer operates in presence of small bias magnetic field. Its salient features are compared with the analysis of Bloch equation. The…
The Bell-Bloom-type optically pumped atomic magnetometers are well suited for weak geomagnetic field detection. However, conventional single-beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy…
A cavity optomechanical magnetometer is demonstrated where the magnetic field induced expansion of a magnetostrictive material is transduced onto the physical structure of a highly compliant optical microresonator. The resulting motion is…
Double-pass polarimetry measures the polarization properties of a sample over a range of polar angles and all azimuths. Here, we present a tolerance analysis of all the optical elements in both the calibration and measurement procedures to…
The nonlinear magneto-optical effect has significantly impacted modern society with prolific applications ranging from precision mapping of the Earth's magnetic field to bio-magnetic sensing. Pioneering works on collisional spin-exchange…
Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multi-pass optical cells. We use a pump-probe measurement scheme to suppress…
We describe an array of spin-exchange relaxation free optical magnetometers designed for detection of fetal magnetocardiography (fMCG) signals. The individual magnetometers are configured with a small volume with intense optical pumping,…
The paper investigates the ellipsometric method of measuring the magneto-optical parameter and optical constants in one experiment at affixed angle of the light incidence in ferromagnetics. The influence of the magnetization modulation on…