English
Related papers

Related papers: Sensitivity of double resonance alignment magnetom…

200 papers

In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive…

Optics · Physics 2024-03-11 A. Akbar , M. Kozbiál , L. Elson , A. Meraki , J. Kolodyński , K. Jensen

We present a theoretical study of the spectra produced by optical-radio-frequency double resonance devices, in which resonant linearly polarized light is used in the optical pumping and detection processes. We extend previous work by…

Atomic Physics · Physics 2007-05-23 Antoine Weis , Georg Bison , Anatoly S. Pazgalev

The operation of a high sensitive atomic magnetometer using resonant elliptically polarized light is demonstrated. The experimental geometry allows autonomous frequency stabilization of the laser, thereby offers compact operation of the…

Atomic Physics · Physics 2016-03-23 S. Pradhan , S. Mishra , R. Behera , Poornima , K. Dasgupta

We present here a new parametric resonance magnetometer scheme based on elliptically polarized pumping light and two radio-frequency fields applied along the two optical pumping directions. At optimum ellipticity and radio-frequency fields…

Atomic Physics · Physics 2021-07-07 Gwenael Le Gal , Laure-Line Rouve , Agustin Palacios-Laloy

Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant…

Atomic Physics · Physics 2017-09-13 Stuart J. Ingleby , Carolyn O'Dwyer , Paul F. Griffin , Aidan S. Arnold , Erling Riis

Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the…

Atomic Physics · Physics 2018-09-26 Stuart J. Ingleby , Carolyn O'Dwyer , Paul F. Griffin , Aidan S. Arnold , Erling Riis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer…

Atomic Physics · Physics 2009-03-16 V. Shah , M. V. Romalis

Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb 85 atoms, in response to change in longitudinal magnetic field (\delta B_z ) is demonstrated…

Instrumentation and Detectors · Physics 2019-04-04 T. J. Vineeth Francis , Rashmi Ranjan Suna , P. K. Madhu , Nirmal K. Viswanathan , G. Rajalakshmi

We present an experimental study of the spectra produced by optical/radio-frequency double resonance in which resonant linearly polarized laser light is used in the optical pumping and detection processes. We show that the experimental…

We study a resonant interaction of an elliptically polarized light wave with $^{87}$Rb vapor (D$_1$ line) exposed to a transverse magnetic field. A $5$$\times$$5$$\times$$5$~mm$^3$ glass vapor cell is used for the experiments. The wave…

An atomic magnetometer operated with elliptically polarized light is investigated theoretically and experimentally. To explore the potential of this magnetometric configuration, the analytical form of the outgoing signal is derived.…

Atomic Physics · Physics 2020-01-08 Shengran Su , Guoyi Zhang , Xin Bi , Xiang He , Wenqiang Zheng , Qiang Lin

Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of…

Applied Physics · Physics 2024-04-12 Adil Meraki , Lucy Elson , Nok Ho , Ali Akbar , Marcin Koźbiał , Jan Kołodyński , Kasper Jensen

A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the sub-microgauss level to above the Earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms…

Atomic Physics · Physics 2009-11-07 D. Budker , D. F. Kimball , V. V. Yashchuk , M. Zolotorev

Optical magnetometers are currently able to achieve magnetometric sensitivities below 1 fT/Hz^1/2. Although such sensitivities are typically obtained for ultra-low-field measurements, a group of optical magnetometers allows the detection of…

Atomic Physics · Physics 2015-06-03 Przemyslaw Wlodarczyk , Szymon Pustelny , Jerzy Zachorowski , Marcin Lipinski

In this work we present a practical algorithm for calibrating a magnetometer for the presence of magnetic disturbances and for magnetometer sensor errors. To allow for combining the magnetometer measurements with inertial measurements for…

Systems and Control · Computer Science 2016-07-15 Manon Kok , Thomas B. Schön

Developing a non-invasive, accurate vector magnetometer that operates at ambient temperature and is conducive to miniaturization and is self-calibrating is a significant challenge. Here, we present an unshielded three-axis vector…

We demonstrate a proof-of-principle magnetometer that relies on the active oscillation of a cold atom Raman laser to continuously map a field-sensitive atomic phase onto the phase of the radiated light. We demonstrate wideband sensitivity…

Atomic Physics · Physics 2015-06-11 Joshua M. Weiner , Kevin C. Cox , Justin G. Bohnet , Zilong Chen , James K. Thompson

The resonant enhancement of mechanical and optical interaction in optomechanical cavities enables their use as extremely sensitive displacement and force detectors. In this work we demonstrate a hybrid magnetometer that exploits the…

We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarisation of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields…

Applied Physics · Physics 2024-07-11 L. M. Rushton , L. M. Ellis , J. D. Zipfel , P. Bevington , W. Chalupczak

A model of dynamic orientation using optimized radiofrequency (RF) irradiation produced perpendicular to the holding field is developed for the spin-1 system required for tensor-polarized fixed-target experiments. The derivation applies to…

Nuclear Theory · Physics 2017-07-25 Dustin Keller
‹ Prev 1 2 3 10 Next ›