Related papers: Pulse-Shape discrimination with the Counting Test …
We developed machine learning algorithms for distinguishing scintillation signals from a plastic-liquid coupled detector known as a phoswich. The challenge lies in discriminating signals from organic scintillators with similar shapes and…
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a…
Pulse shape discrimination (PSD) is crucial for non-proliferation and security applications, where fast neutrons need to be identified and measured in the presence of a strong gamma-ray background. The traditional charge-integration-based…
Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…
A brief outline of Dark Matter detection experiments using liquid argon technology is presented. The Pulse Shape background discrimination method (PSD) is described and the example of its use in 2.3 l R&D detector is given. Methods of…
Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…
Purification of the 278 tons of liquid scintillator and 889 tons of buffer shielding for the Borexino solar neutrino detector was performed with a system that combined distillation, water extraction, gas stripping and filtration. The…
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The…
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of…
We report the performance and characterization of a custom-built hybrid detector consisting of BC501A liquid scintillator for fast neutrons and BC702 scintillator for thermal neutrons. The calibration and the resolution of the BC501A liquid…
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis.…
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination…
Borexino is a large unsegmented calorimeter featuring 300 tons of liquid scintillator, contained in a 8.5 meter nylon vessel, viewed by 2200 PMTs. The main goal of Borexino is the study, in real time, of low energy solar neutrinos, and in…
Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…
In this paper, we present an investigation into the scintillation properties and pulse shape discrimination (PSD) performance of the new BSO-406, which is a blend of 40% organic glass scintillator and 60% polystyrene. We tested a…
A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or…
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing…
Detection of scintillation light can play several important roles in LArTPCs. Increased collection efficiency could result in the improvement of time, energy, and position resolution. The SBND collaboration is developing detailed MC…
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…
Pulse shape discriminating scintillator materials in many cases allow the user to identify two basic kinds of pulses arising from two kinds of particles: neutrons and gammas. An uncomplicated solution for building a classifier consists of a…