Related papers: Phase Closure at 691 GHz using the Submillimeter A…
We present the first high spectral resolution observations of Orion KL in the frequency ranges 1573.4 - 1702.8 GHz (band 6b) and 1788.4 - 1906.8 GHz (band 7b) obtained using the HIFI instrument on board the Herschel Space Observatory. We…
We use the Atacama Large sub/Millimetre Array (ALMA) to efficiently observe spectral lines across Bands 3, 4, 5, 6, 7, and 8 at high-resolution (0.5" - 0.1") for 16 bright southern Herschel sources at $1.5 < z < 4.2$. With only six and a…
Classical sensors for spectrum analysis are widely used but lack micro- or nanoscale spatial resolution. On the other hand, quantum sensors, capable of working with nanoscale precision, do not provide precise frequency resolution over a…
A new multichannel spectrometer, Phoenix-3, is in operation having capabilities to observe solar flare radio emissions in the 0.1 - 5 GHz range at an unprecedented spectral resolution of 61.0 kHz with high sensitivity. The present setup for…
Ultra-high energy (UHE) neutrinos and cosmic rays initiate particle cascades underneath the Moon's surface. These cascades have a negative charge excess and radiate Cherenkov radio emission in a process known as the Askaryan effect. The…
We present a result of the quasar CO(J=6-5) observations of SDSSp J104433.04-012502.2 at z = 5.8. Ten-days observations with the Nobeyama Millimeter Array yielded an rms noise level of ~ 2.1 mJy/beam in a frequency range from 101.28 GHz to…
We use numerical simulations of cosmic reionization and radiative processes related to the HI 21 cm emission line to produce synthetic radio maps as seen by next generation radio telescopes that will operate at low radio frequencies (e.g.…
The Naval Research Laboratory and the National Radio Astronomy Observatory completed implementation of a low frequency capability on the VLA at 73.8 MHz in 1998. This frequency band offers unprecedented sensitivity (~25 mJy/beam) and…
We have upgraded the 60-cm radio survey telescope located in Nobeyama, Japan. We developed a new waveguide-type sideband-separating SIS mixer for the telescope, which enables the simultaneous detection of distinct molecular emission lines…
For the submillimeter band observations, we have been routinely adopting the calibration cycle time of 20-30 minutes, which is the same as any typical centimeter and millimeter band observations. This cycle time, largely corrects only the…
By direct measurements of the gas temperature, the Atacama Large Millimeter/sub-millimeter Array (ALMA) has yielded a new diagnostic tool to study the solar chromosphere. Here we present an overview of the brightness-temperature…
We have measured new submillimeter-wave data around 600 GHz and around 1.1 THz for the 13C isotopologue of formic acid and for the two deuterium isotopomers; in each case for both the trans and cis rotamer. For cis-DCOOH and cis-HCOOD in…
The Allen Telescope Array was used to monitor Mars between 9 March and 2 June 2010, over a total of approximately 30 hours, for radio emission indicative of electrostatic discharge. The search was motivated by the report from Ruf et al.…
We use the Low Frequency Array to perform a systematic high spectral resolution investigation of the low-frequency 33-78 MHz spectrum along the line of sight to Cassiopeia A. We complement this with a 304-386 MHz Westerbork Synthesis Radio…
We present the sub-millimeter spectra from 450 GHz to 1550 GHz of eleven nearby active galaxies observed with the SPIRE Fourier Transform Spectrometer (SPIRE/FTS) onboard Herschel. We detect CO transitions from J_up = 4 to 12, as well as…
We have surveyed molecular line emission from Orion BN/KL from 42.3 to 43.6 GHz with the Green Bank Telescope. Sixty-seven lines were identified and ascribed to 13 different molecular species. The spectrum at 7 mm is dominated by SiO, SO2,…
The Atacama Large millimeter/submillimeter Array (ALMA) obtains spatial resolutions of 15 to 5 milli-arcsecond (mas) at 275-950GHz (0.87-0.32mm) with 16km baselines. Calibration at higher-frequencies is challenging as ALMA sensitivity and…
Precise measurements of the frequency and phase of an electrical or optical signal play a key role in various branches of science and engineering. Tracking changing laser frequencies is especially demanding when the lasers themselves are…
In April 2002 an array of antennas operating at 129GHz successfully detected VLBI fringes on both continuum AGN and SiO maser sources. The 129GHz fringes on maser sources represent the highest frequency spectral line VLBI detections to…
We have frequency stabilized a Coherent CR699-21 dye laser to a transient spectral hole on the 606 nm transition in Pr^{+3}:Y_2SiO_5. A frequency stability of 1 kHz has been obtained on the 10 microsecond timescale together with a long-term…