Related papers: Theoretical study of the accuracy limits for the o…
The nonresonant (NR) corrections are estimated for the most accurately measured two-photon transition 1s-2s in the hydrogen atom. These corrections depend on the measurement process and set a limit for the accuracy of atomic frequency…
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency…
We present a measurement of the hydrogen $2$S$_{1/2}-8$D$_{5/2}$ transition performed with a cryogenic atomic beam. The measured resonance frequency is $\nu=770649561570.9(2.0)$ kHz, which corresponds to a relative uncertainty of…
Using the Dirac equation, radiative corrections and finite nuclear size and mass corrections, we calculate the $1s$-$2s$ quantum transition frequency $f_{1s,2s}$ of hydrogen and its uncertainty due to the uncertainties $\delta m_e, \delta…
This article reports the first optical frequency measurement of the $1\mathrm{S}-3\mathrm{S}$ transition in hydrogen. The excitation of this transition occurs at a wavelength of 205 nm which is obtained with two frequency doubling stages of…
We present absolute frequency measurements of 2S_{1/2}-nS_{1/2} two-photon transitions with n = 8, 9, and 10 in a cryogenic beam of atomic hydrogen. Each transition has been measured with a fractional uncertainty of approximately…
We present the first precise frequency measurement of the 2$^{1}$S$_{0}$-3$^{1}$D$_{2}$ two-photon transition in $^{4}$He at 1009 nm. The laser source at 1009 nm is stabilized on an optical frequency comb to perform the absolute frequency…
We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of $9\times10^{-13}$. The…
An optical measurement of the 2S hyperfine interval in atomic hydrogen using two-photon spectroscopy of the 1S-2S transition gives a value of 177 556 834.3(6.7) Hz. The uncertainty is 2.4 times smaller than achieved by our group in 2003 and…
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating…
We demonstrate a technique for frequency measurements of atomic transitions with a precision of 30 kHz. The frequency is measured using a ring-cavity resonator whose length is calibrated against a reference laser locked to the $D_2$ line of…
We report the frequency measurement with an accuracy in the 100 kHz range of several optical transitions of atomic Sr : $^1S_0- ^3P_1$ at 689 nm, $^3P_1- ^3S_1$ at 688 nm and $^3P_0- ^3S_1$ at 679 nm. Measurements are performed with a…
We report a new determination of muonium 1S-2S transition frequency and its isotope shift with deuterium by recalibrating the iodine reference lines using an optical frequency comb. The reference lines for the muonium and deuterium 1S-2S…
The resonant spectra of hydrogen and anti-hydrogen atoms in the presence of an external electric field are compared theoretically. It is shown that nonresonant corrections to the transition frequency contain terms linear in the electric…
We have applied an optical method to the measurement of the 2S hyperfine interval in atomic hydrogen. The interval has been measured by means of two-photon spectroscopy of the 1S-2S transition on a hydrogen atomic beam shielded from…
There are few good direct laboratory tests of boost invariance for electrons, because the experiments required often involve repeated precision measurements performed at different times of year. However, existing measurements and…
We developed a novel technique for frequency measurement and synthesis, based on the operation of a femtosecond comb generator as transfer oscillator. The technique can be used to measure frequency ratios of any optical signals throughout…
We examine the precision limits of Hong-Ou-Mandel (HOM) timing measurements, as well as precision limits applying to generalized two-photon measurements. As a special case, we consider the use of two-photon measurements using photons with…
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave…
The ultimate sensitivity of optical measurements is a key element of many recent works. Classically, it is mainly limited by the shot noise limit. However, a measurement setup that incorporates quantum mechanical principles can surpass the…