Related papers: Limits on WIMP-nucleon interactions with CsI(Tl) c…
New limits are presented on the cross section for Weakly Interacting Massive Particle (WIMP) nucleon scattering in the KIMS CsI(T) detector array at the Yangyang Underground Laboratory. The exposure used for these results is 24524.3…
We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting massive particles(WIMPs), strong candidates of dark matter particles,using the low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS)…
New constraints are presented on the spin-dependent WIMP-nucleon interaction from the PandaX-II experiment, using a data set corresponding to a total exposure of 3.3$\times10^4$ kg-days. Assuming a standard axial-vector spin-dependent WIMP…
Limits on the cross section for weakly interacting massive particles (WIMPs) scattering off nucleons in the NaI(Tl) detectors at the Yangyang Underground Laboratory are obtained with a 2967.4 kg*day data exposure. Nuclei recoiling are…
We report new results from the Cryogenic Dark Matter Search (CDMS II) at the Soudan Underground Laboratory. Two towers, each consisting of six detectors, were operated for 74.5 live days, giving spectrum-weighted exposures of 34 kg-d for…
The Cryogenic Dark Matter Search (CDMS) employs Ge and Si detectors to search for WIMPs via their elastic-scattering interactions with nuclei while discriminating against interactions of background particles. CDMS data give limits on the…
Spin-dependent WIMP searches have traditionally presented results within an odd group approximation and by suppressing one of the spin-dependent interaction cross sections. We here elaborate on a model-independent analysis in which…
The Korea Invisible Mass Search (KIMS) collaboration has been carrying out WIMP search experiment with CsI(T$\ell$)crystal detectors at the YanYang Underground Laboratory. A successful reduction of the internal background of the crystal is…
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded.…
The Cryogenic Dark Matter Search (CDMS) is an experiment to detect weakly interacting massive particles (WIMPs) based on their interactions with Ge and Si nuclei. We report the results of an analysis of data from the first two runs of CDMS…
We report new limits on spin-independent WIMP-nucleon interaction cross-section using 39.5 kg-days of data taken with a p-type point-contact germanium detector of 840 g fiducial mass at the Kuo-Sheng Reactor Neutrino Laboratory. Crucial to…
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected…
The SIMPLE project uses superheated C2ClF5 liquid detectors to search for particle dark matter candidates. We report the results of the first stage exposure (14.1 kgd) of its latest two-stage, Phase II run, with 15 superheated droplet…
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and…
The PICASSO experiment reports an improved limit for the existence of cold dark matter WIMPs interacting via spin-dependent interactions with nuclei. The experiment is installed in the Sudbury Neutrino Observatory at a depth of 2070 m. With…
New results after 0.69 kg yr of measurement with an enriched 76Ge detector of the Heidelberg--Moscow experiment with an active mass of 2.758 kg are presented. An energy threshold of 9 keV and a background level of 0.042 counts/(kg d keV) in…
We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to…
We perform a generalized analysis of data from WIMP search experiments for point-like WIMPs of arbitrary spin and general Lorenz-invariant WIMP-nucleus interaction. We show that in the non-relativistic limit only spin-independent (SI) and…
The Cryogenic Dark Matter Search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering interaction with the target nuclei. The current analysis of 397.8 kg-days Ge exposure resulted in…
The Cryogenic Dark Matter Search (CDMS) employs low-temperature Ge and Si detectors to search for Weakly Interacting Massive Particles (WIMPs) via their elastic-scattering interactions with nuclei while discriminating against interactions…