Vacuum magnetic linear birefringence using pulsed fields: the BMV experiment

Optics 2015-06-15 v3 High Energy Physics - Experiment

Abstract

We present the current status of the BMV experiment. Our apparatus is based on an up-to-date resonant optical cavity coupled to a transverse magnetic field. We detail our data acquisition and analysis procedure which takes into account the symmetry properties of the raw data with respect to the orientation of the magnetic field and the sign of the cavity birefringence. The measurement result of the vacuum magnetic linear birefringence k_\mathrm{CM}presentedinthispaperwasobtainedwithabout200magneticpulsesandamaximumfieldof6.5T,givinganoisefloorofabout presented in this paper was obtained with about 200 magnetic pulses and a maximum field of 6.5\,T, giving a noise floor of about 8 \times 10^{-21}T\,T^{-2}at at 3\sigma$ confidence level.

Keywords

Cite

@article{arxiv.1302.5389,
  title  = {Vacuum magnetic linear birefringence using pulsed fields: the BMV experiment},
  author = {A. Cadène and P. Berceau and M. Fouché and R. Battesti and C. Rizzo},
  journal= {arXiv preprint arXiv:1302.5389},
  year   = {2015}
}