English

Universal Non-Intrusive Load Monitoring (UNILM) Using Filter Pipelines, Probabilistic Knapsack, and Labelled Partition Maps

Signal Processing 2019-07-26 v2

Abstract

Being able to track appliances energy usage without the need of sensors can help occupants reduce their energy consumption to help save the environment all while saving money. Non-intrusive load monitoring (NILM) tries to do just that. One of the hardest problems NILM faces is the ability to run unsupervised -- discovering appliances without prior knowledge -- and to run independent of the differences in appliance mixes and operational characteristics found in various countries and regions. We propose a solution that can do this with the use of an advanced filter pipeline to preprocess the data, a Gaussian appliance model with a probabilistic knapsack algorithm to disaggregate the aggregate smart meter signal, and partition maps to label which appliances were found and how much energy they use no matter the country/region. Experimental results show that relatively complex appliance signals can be tracked accounting for 93.7% of the total aggregate energy consumed.

Keywords

Cite

@article{arxiv.1907.06299,
  title  = {Universal Non-Intrusive Load Monitoring (UNILM) Using Filter Pipelines, Probabilistic Knapsack, and Labelled Partition Maps},
  author = {Alejandro Rodriguez-Silva and Stephen Makonin},
  journal= {arXiv preprint arXiv:1907.06299},
  year   = {2019}
}