English

The Virgo Newtonian calibration system for the O4 observing run

General Relativity and Quantum Cosmology 2024-10-30 v3

Abstract

After initial tests performed during previous observing runs, a Newtonian Calibrator (NCal) system was developed and installed on the Virgo gravitational wave detector for the O4 observing run. This system, which is continuously operated, provides the absolute calibration of Virgo for this run. Its 1\mboxσ1\mbox{-}\sigma uncertainty of 0.17%0.17\% on the amplitudes of the injected signals is better than that obtained with other calibration techniques like the photon calibrator (PCal). This paper presents this NCal system and details the different sources of uncertainties

Keywords

Cite

@article{arxiv.2406.10028,
  title  = {The Virgo Newtonian calibration system for the O4 observing run},
  author = {Florian Aubin and Eddy Dangelser and Dimitri Estevez and Alain Masserot and Benoît Mours and Thierry Pradier and Antoine Syx and Pierre Van Hove},
  journal= {arXiv preprint arXiv:2406.10028},
  year   = {2024}
}

Comments

Class. Quantum Grav (2024)