English

The CMS ECAL Trigger and DAQ system: electronics auto-recovery and monitoring

Instrumentation and Detectors 2018-07-24 v2 High Energy Physics - Experiment

Abstract

In 2017, the LHC (Large Hadron Collider) at CERN has obtained an astonishing result providing proton-proton collisions with an integrated luminosity of 50.25 fb-1. The CMS (Compact Muon Solenoid), a general-purpose detector operating at the LHC, has been able to record 45.39 fb-1. ECAL (Electromagnetic Calorimeter), has shown a good performance with a very stable DAQ (Data Acquisition) system even during higher LHC luminosity peaks. This has been partly because of the electronics auto-recovery system that has been developed to identify errors like SEU (Single Event Upset) and to resolve them. A new monitoring system has been developed called ecalView which is used for monitoring the errors from different electronics of the ECAL and to keep a log of these errors in a database for future reference.

Keywords

Cite

@article{arxiv.1806.09136,
  title  = {The CMS ECAL Trigger and DAQ system: electronics auto-recovery and monitoring},
  author = {Prasanna Kumar Siddireddy},
  journal= {arXiv preprint arXiv:1806.09136},
  year   = {2018}
}

Comments

7 pages, 6 figues, 1 table, conference record