The Neutrinos at the Main Injector (NuMI) facility is a conventional neutrino beam which produces muon neutrinos by focusing a beam of mesons into a long evacuated decay volume. We have built four arrays of ionization chambers to monitor the position and intensity of the hadron and muon beams associated with neutrino production at locations downstream of the decay volume. This article describes the chambers' construction, calibration, and commissioning in the beam.
Cite
@article{arxiv.physics/0607229,
title = {Secondary Beam Monitors for the NuMI Facility at FNAL},
author = {S. Kopp and M. Bishai and M. Dierckxsens and M. Diwan and A. R. Erwin and D. A. Harris and D. Indurthy and R. Keisler and M. Kostin and M. Lang and J. MacDonald and A. Marchionni and S. Mendoza and J. Morfin and D. Naples and D. Northacker and Z. Pavlovic and L. Phelps and H. Ping and M. Proga and C. Vellissaris and B. Viren and R. Zwaska},