English

Robust peak detection for photoplethysmography signal analysis

Medical Physics 2023-07-21 v1

Abstract

Efficient and accurate evaluation of long-term photoplethysmography (PPG) recordings is essential for both clinical assessments and consumer products. In 2021, the top opensource peak detectors were benchmarked on the Multi-Ethnic Study of Atherosclerosis (MESA) database consisting of polysomnography (PSG) recordings and continuous sleep PPG data, where the Automatic Beat Detector (Aboy) had the best accuracy. This work presents Aboy++, an improved version of the original Aboy beat detector. The algorithm was evaluated on 100 adult PPG recordings from the MESA database, which contains more than 4.25 million reference beats. Aboy++ achieved an F1-score of 85.5%, compared to 80.99% for the original Aboy peak detector. On average, Aboy++ processed a 1 hour-long recording in less than 2 seconds. This is compared to 115 seconds (i.e., over 57-times longer) for the open-source implementation of the original Aboy peak detector. This study demonstrated the importance of developing robust algorithms like Aboy++ to improve PPG data analysis and clinical outcomes. Overall, Aboy++ is a reliable tool for evaluating long-term wearable PPG measurements in clinical and consumer contexts.

Cite

@article{arxiv.2307.10398,
  title  = {Robust peak detection for photoplethysmography signal analysis},
  author = {Márton Á. Goda and Peter H. Charlton and Joachim A. Behar},
  journal= {arXiv preprint arXiv:2307.10398},
  year   = {2023}
}

Comments

4 pages, 1 figure, 50th Computing in Cardiology conference in Atlanta, Georgia, USA on 1st - 4th October 2023

R2 v1 2026-06-28T11:35:15.904Z