English

Reduced Effective Model for Condensation in Slender Tubes with Rotational Symmetry, Obtained by Generalized Dimensional Analysis

Fluid Dynamics 2015-03-18 v1

Abstract

Experimental results for condensation in compact heat exchangers show that the heat transfer due to condensation is significantly better compared to classical heat exchangers, especially when using R134a instead of water as the refrigerant. This suggests that surface tension plays a role. Using generalized dimensional analysis we derive reduced model equations and jump conditions for condensation in a vertical tube with cylindrical cross section. Based on this model we derive a single ordinary differential equation for the thickness of the condensate film as function of the tube axis. Our model agrees well with commonly used models from existing literature. It is based on the physical dimensions of the problem and has greater geometrical flexibility.

Keywords

Cite

@article{arxiv.1101.5718,
  title  = {Reduced Effective Model for Condensation in Slender Tubes with Rotational Symmetry, Obtained by Generalized Dimensional Analysis},
  author = {Andrea Dziubek},
  journal= {arXiv preprint arXiv:1101.5718},
  year   = {2015}
}