English

Precise determination of micromotion for trapped-ion optical clocks

Atomic Physics 2015-11-18 v3 Quantum Physics

Abstract

As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low 101810^{-18} range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below 1×10201\times 10^{-20} can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of 101910^{-19} is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of 1×10201\times 10^{-20} as well.

Keywords

Cite

@article{arxiv.1505.05907,
  title  = {Precise determination of micromotion for trapped-ion optical clocks},
  author = {J. Keller and H. L. Partner and T. Burgermeister and T. E. Mehlstäubler},
  journal= {arXiv preprint arXiv:1505.05907},
  year   = {2015}
}

Comments

13 pages, 13 figures