Pixel column issue in the ATLAS Inner Tracker modules
Abstract
Pixel modules are currently being built for the ATLAS ITk Pixel detector upgrade. During the preproduction phase, recurring chip malfunctioning was observed during electrical testing. It was possible to bypass this issue by disabling some pixel core columns in the ITkPix readout chip. Therefore the issue is called "core column issue" which is a direct disqualifier for a pixel module. A concerning number of cases has been observed in pixel modules with ITkPix v1.1 as well as v2 chips which significantly impacts the module yield. However, the behaviour is erratic and there is not any evidence hinting at the origin of this issue. These proceedings outline the investigations of the issue, highlighting the electrical behaviour during testing, present findings from the data collected via our production database and through visual inspection, and point towards possible causes of the issue.
Keywords
Cite
@article{arxiv.2505.10528,
title = {Pixel column issue in the ATLAS Inner Tracker modules},
author = {L. Meng and R. Bates and C. Buttar and G. Calderini and F. Crescioli and L. Cunningham and Y. Dieter and R. Han and T. Heim and S. Hirose and F. Huegging and C. Hultquist and D. Kim and A. Korn and M. Marjanovic and J. Metcalfe and K. Nakamura and J. Pater and H. Pernegger and M. A. A. Samy and M. Schuessler and A. Sharma and E. Thompson and M. Backhaus and J. Christiansen and F. Loddo},
journal= {arXiv preprint arXiv:2505.10528},
year = {2025}
}
Comments
8 pages, 11 figures, 20th Anniversary Trento Workshop on Advanced Silicon Radiation Detectors 4--6 February 2025