English

Physics Design Considerations of Diagnostic X Beam Transport System

Accelerator Physics 2007-05-23 v1

Abstract

Diagnostic X (D-X) transport system would extract the beam from the downstream transport line of the second- axis of the Dual Axis Radiographic Hydrodynamic Test facility (DARHT-II) and transport this beam to the D-X firing point via four branches of the beamline in order to provide four lines of sight for x-ray radiography. The design goal is to generate four DARHT-II-like x-ray pulses on each line of sight. In this paper, we discuss several potential beam quality degradation processes in the passive magnet lattice beamline and indicate how they constrain the D-X beamline design parameters, such as the background pressure, the pipe size, and the pipe material

Keywords

Cite

@article{arxiv.physics/0008118,
  title  = {Physics Design Considerations of Diagnostic X Beam Transport System},
  author = {Yu-Jiuan Chen and Arthur C. Paul},
  journal= {arXiv preprint arXiv:physics/0008118},
  year   = {2007}
}

Comments

3 pages, 0 figures, LINAC 2000, TBU20