Abstract

In this work the extraction of pulse time and amplitude from short pulse transients is analysed as they are recorded by a transient recorder ASIC called ATR16. Algorithms of different complexity are tested with simulated preamplifier data processed with a VHDL model of the ATR16 ASIC. It is shown that a time precision below 1 ns and a signal amplitude precision below 1 MeV energy equivalent is feasible.