English

Pareto-Optimal Model Selection for Low-Cost, Single-Lead EMG Control in Embedded Systems

Human-Computer Interaction 2026-01-13 v1 Machine Learning Signal Processing

Abstract

Consumer-grade biosensors offer a cost-effective alternative to medical-grade electromyography (EMG) systems, reducing hardware costs from thousands of dollars to approximately $13. However, these low-cost sensors introduce significant signal instability and motion artifacts. Deploying machine learning models on resource-constrained edge devices like the ESP32 presents a challenge: balancing classification accuracy with strict latency (<100ms) and memory (<320KB) constraints. Using a single-subject dataset comprising 1,540 seconds of raw data (1.54M data points, segmented into ~1,300 one-second windows), I evaluate 18 model architectures, ranging from statistical heuristics to deep transfer learning (ResNet50) and custom hybrid networks (MaxCRNN). While my custom "MaxCRNN" (Inception + Bi-LSTM + Attention) achieved the highest safety (99% Precision) and robustness, I identify Random Forest (74% accuracy) as the Pareto-optimal solution for embedded control on legacy microcontrollers. I demonstrate that reliable, low-latency EMG control is feasible on commodity hardware, with Deep Learning offering a path to near-perfect reliability on modern Edge AI accelerators.

Keywords

Cite

@article{arxiv.2601.06516,
  title  = {Pareto-Optimal Model Selection for Low-Cost, Single-Lead EMG Control in Embedded Systems},
  author = {Carl Vincent Ladres Kho},
  journal= {arXiv preprint arXiv:2601.06516},
  year   = {2026}
}

Comments

15 pages main text, 51 pages total including appendices. 18 figures. Code and dataset available at: https://github.com/CarlKho-Minerva/v2-emg-muscle

R2 v1 2026-07-01T08:58:53.347Z