English

Overlap Technique for End-Cap Seals on Cylindrical Magnetic Shields

Instrumentation and Detectors 2013-07-04 v1

Abstract

We present results from studies of the effectiveness of an overlap technique for forming a magnetic seal across a gap at the boundary between a cylindrical magnetic shield and an end-cap. In this technique a thin foil of magnetic material overlaps the two surfaces, thereby spanning the gap across the cylinder and the end-cap, with the magnetic seal then formed by clamping the thin magnetic foil to the surfaces of the cylindrical shield and the end-cap on both sides of the gap. In studies with a prototype 31-cm diameter, 91-cm long, 0.16-cm thick cylindrical magnetic shield and flared end-cap, the magnetic shielding performance of our overlap technique is comparable to that obtained with the conventional method in which the end-cap is placed in direct lapped contact with the cylindrical shield via through bolts or screws.

Cite

@article{arxiv.1307.0866,
  title  = {Overlap Technique for End-Cap Seals on Cylindrical Magnetic Shields},
  author = {S. Malkowski and R. Y. Adhikari and J. Boissevain and C. Daurer and B. W. Filippone and B. Hona and B. Plaster and D. Woods and H. Yan},
  journal= {arXiv preprint arXiv:1307.0866},
  year   = {2013}
}

Comments

4 pages, 5 figures

R2 v1 2026-06-22T00:44:34.956Z