Noise Suppression via Pulsed All-Optical Magnetometry with Nitrogen-Vacancy Ensembles
Abstract
All-optical (AO) microwave-free magnetometry using nitrogen-vacancy (NV) centers in diamond simplifies experimental design and broadens sample compatibility. While continuous-wave (cw) detection of AO photoluminescence (PL) changes is commonly employed, its performance is susceptible to systematic fluctuations such as optical intensity noise. To address these challenges, we introduce a pulsed AO protocol that employs two PL measurements within an optical pulse to suppress common-mode noise. At near-zero magnetic field, we experimentally demonstrate that the pulsed AO protocol resolves AO-PL contrast features arising from NV-NV cross-relaxation, achieving up to 10 improvement in the low-frequency noise floor compared to conventional cw AO techniques. We further investigate the dependence of AO-PL contrast on PL readout timing and the dark time duration between optical pulses, with the optimal varying based on NV concentrations. These findings provide insights into optimizing NV-diamond samples for effective AO operation across diverse applications.
Cite
@article{arxiv.2607.01615,
title = {Noise Suppression via Pulsed All-Optical Magnetometry with Nitrogen-Vacancy Ensembles},
author = {Xiechen Zheng and Jeyson Támara-Isaza and John W. Blanchard and Ronald L. Walsworth},
journal= {arXiv preprint arXiv:2607.01615},
year = {2026}
}
Comments
9 pages, 8 figures