English

Impact of Motor Stator Winding Faults on Common-Mode Current

Systems and Control 2021-10-07 v1 Systems and Control Classical Physics

Abstract

This paper investigates the influence of different motor stator failures on the common-mode (CM) current. The stator winding failures will affect the motor's CM impedance, and also increase the unbalance of the differential-mode (DM) noise path. The experimental results show that the former will increase the CM current induced by the CM noise source, while the latter will cause the DM current induced by the DM noise source to be converted into the CM current.

Keywords

Cite

@article{arxiv.2110.02427,
  title  = {Impact of Motor Stator Winding Faults on Common-Mode Current},
  author = {Fei Fan and Zhenyu Zhao and Pengfei Tu and Huamin Jie and Kye Yak See},
  journal= {arXiv preprint arXiv:2110.02427},
  year   = {2021}
}

Comments

The conference paper has been accepted by APEMC 2021, which is to be published in IEEE Xplore soon