English

HERA Transverse Polarimeter absolute scale and error by rise-time calibration

High Energy Physics - Experiment 2007-05-23 v1

Abstract

We give the results of an analysis of some 18 rise-time calibrations which are based on data collected in 1996/97. Such measurements are used to determine the absolute polarization scale of the transverse electron beam polarimeter (TPOL) at HERA. The results of the 1996/97 calibrations are found to be in good agreement with earlier calibrations of the TPOL performed in 1994 with errors of 1.2% and 1.1%. Based on these calibrations and a comparison with measurements from the longitudinal polarimeter (LPOL) at HERA carried out over a two-months period in 2000, we obtain a mean LPOL/TPOL ratio of 1.018. Both polarimeters are found to agree with each other within their overall errors of about 2% each.

Keywords

Cite

@article{arxiv.hep-ex/0310045,
  title  = {HERA Transverse Polarimeter absolute scale and error by rise-time calibration},
  author = {V. Gharibyan and K. P. Schuler},
  journal= {arXiv preprint arXiv:hep-ex/0310045},
  year   = {2007}
}

Comments

8 pages, 2 figures, Contributed to NATO Advanced Research Workshop on Spin Structure of the Nucleon, June 29-July 4, 2002, Nor-Amberd, Armenia

R2 v1 2026-07-22T13:02:56.883Z