English

First (calibration) experiment using proton beam from FRENA at SINP

Instrumentation and Detectors 2024-02-07 v1 Nuclear Experiment Accelerator Physics

Abstract

This work presents the first calibration experiment of a 3 MV Tandetron accelerator, FRENA, performed in May 2022. The 7^7Li(p,n) reaction threshold was measured to calibrate the terminal voltage measuring device. A LiF target of thickness 175 μ\mug/cm2^2 was used in the experiment. The measured threshold was 1872±\pm2.7 keV, indicating 6-10 keV energy shift.

Keywords

Cite

@article{arxiv.2402.03344,
  title  = {First (calibration) experiment using proton beam from FRENA at SINP},
  author = {C. Basu and K. Banerjee and T. K. Ghosh and G. Mukherjee and C. Bhattacharya and Shraddha S Desai and R. Shil and A. K. Saha and J. K. Meena and T. Bar and D. Basak and L. K. Sahoo and S. Saha and C. Marick and D. Das and D. Das and D. Das and M. Kujur and S. Roy and S. S. Basu and U. Gond and A. Saha and A. Das and M. Samanta and P. Saha and S. K. Karan},
  journal= {arXiv preprint arXiv:2402.03344},
  year   = {2024}
}
R2 v1 2026-06-28T14:39:04.199Z