This study explores the dynamics of charge transport within a cryogenic P-type Ge particle detector, fabricated from a crystal cultivated at the University of South Dakota (USD). By subjecting the detector to cryogenic temperatures and an Am-241 source, we observe evolving charge dynamics and the emergence of cluster dipole states, leading to the impact ionization process at 40 mK. Our analysis focuses on crucial parameters: the zero-field cross-section of cluster dipole states and the binding energy of these states. For the Ge detector in our investigation, the zero-field cross-section of cluster dipole states is determined to be 8.45×10−11±4.22×10−12cm2. Examination of the binding energy associated with cluster dipole states, formed by charge trapping onto dipole states during the freeze-out process, reveals a value of 0.034±0.0017 meV. These findings shed light on the intricate charge states influenced by the interplay of temperature and electric field, with potential implications for the sensitivity in detecting low-mass dark matter.
@article{arxiv.2402.18388,
title = {Exploring Charge Transport Dynamics in a Cryogenic P-Type Germanium Detector},
author = {P. Acharya and M. Fritts and D. -M. Mei and G. -J. Wang and R. Mahapatra and M. Platt},
journal= {arXiv preprint arXiv:2402.18388},
year = {2024}
}