English

Experimental Test of a Two-dimensional Approximation for Dielectric Microcavities

Optics 2009-08-31 v1

Abstract

Open dielectric resonators of different shapes are widely used for the manufacture of microlasers. A precise determination of their resonance frequencies and widths is crucial for their design. Most microlasers have a flat cylindrical geometry, and a two-dimensional approximation, the so-called method of the effective index of refraction, is commonly employed for numerical calculations. Our aim has been an experimental test of the precision and applicability of a model based on this approximation. We performed very thorough and accurate measurements of the resonance frequencies and widths of two passive circular dielectric microwave resonators and found significant deviations from the model predictions. From this we conclude that the model generally fails in the quantitative description of three-dimensional dielectric resonators.

Keywords

Cite

@article{arxiv.0908.0598,
  title  = {Experimental Test of a Two-dimensional Approximation for Dielectric Microcavities},
  author = {S. Bittner and B. Dietz and M. Miski-Oglu and P. Oria Iriarte and A. Richter and F. Schäfer},
  journal= {arXiv preprint arXiv:0908.0598},
  year   = {2009}
}

Comments

10 pages, 13 figures

R2 v1 2026-06-21T13:32:34.160Z