Computational imaging systems -- from coded-aperture cameras to cryo-electron microscopes -- span five carrier families yet share a hidden structural simplicity. We prove that every imaging forward model decomposes into a directed acyclic graph over exactly 11 physically typed primitives (Finite Primitive Basis Theorem) -- a sufficient and minimal basis that provides a compositional language for designing any imaging modality. We further prove that every reconstruction failure has exactly three independent root causes: information deficiency, carrier noise, and operator mismatch (Triad Decomposition). The three gates map to the system lifecycle: Gates 1 and 2 guide design (sampling geometry, carrier selection); Gate 3 governs deployment-stage calibration and drift correction. Validation across 12 modalities and all five carrier families confirms both results, with +0.8 to +13.9 dB recovery on deployed instruments. Together, the 11 primitives and 3 gates establish the first universal grammar for designing, diagnosing, and correcting computational imaging systems.
@article{arxiv.2603.13521,
title = {Eleven Primitives and Three Gates: The Universal Structure of Computational Imaging},
author = {Chengshuai Yang and Xin Yuan},
journal= {arXiv preprint arXiv:2603.13521},
year = {2026}
}
Comments
39 pages, 5 figures, 2 extended data tables, supplementary information