English

Development of A Modified Quasi-periodic Undulator for HLS

Accelerator Physics 2013-08-26 v1 Instrumentation and Detectors

Abstract

A modified quasi periodic undulator (QPU) is developed and to be installed at Hefei Light Source (HLS).Magnet dimensions optimization is applied. High harmonics contamination is eliminated from the fundamental emission effectively according to the field tests. The depression ratio of 3rd harmonic is increased by an order of magnitude than the current device with other harmonics well reduced simultaneously. The significance of the modification measure is verified practically. The design, measurement and commissioning of the device is described.

Keywords

Cite

@article{arxiv.1308.5025,
  title  = {Development of A Modified Quasi-periodic Undulator for HLS},
  author = {Yufeng Yang and Huihua Lu and Wan chen and Qika Jia and Shuchen Sun and Zhiqiang Li},
  journal= {arXiv preprint arXiv:1308.5025},
  year   = {2013}
}

Comments

7 pages, 5 figures, 4 tables