English

Controlling the accuracy of unconditionally stable algorithms in Cahn-Hilliard Equation

Materials Science 2007-05-23 v2 Soft Condensed Matter

Abstract

Given an unconditionally stable algorithm for solving the Cahn-Hilliard equation, we present a general calculation for an analytic time step \dτ\d \tau in terms of an algorithmic time step \dt\dt. By studying the accumulative multi-step error in Fourier space and controlling the error with arbitrary accuracy, we determine an improved driving scheme \dt=At2/3\dt=At^{2/3} and confirm the numerical results observed in a previous study \cite{Cheng1}.

Keywords

Cite

@article{arxiv.cond-mat/0609354,
  title  = {Controlling the accuracy of unconditionally stable algorithms in Cahn-Hilliard Equation},
  author = {Mowei Cheng and James A. Warren},
  journal= {arXiv preprint arXiv:cond-mat/0609354},
  year   = {2007}
}

Comments

4 pages, latex