English

Constraints for precise and accurate fluid inclusion stable isotope analysis using water-vapour saturated CRDS techniques

Geophysics 2023-01-05 v1

Abstract

Hydrogen (δ\delta2H) and oxygen (δ\delta18O) isotopes of water extracted from speleothem fluid inclusions are important proxies used for paleoclimate reconstruction. In our study we use a cavity ring-down laser spectroscopy system for analysis and modified the approach of Affolter et al. (2014) for sample extraction. The method is based on crushing of small sub-gram speleothem samples in a heated and continuously water-vapour purged extraction line. The following points were identified: Injection of reference water shows a precision (1σ\sigma) of 0.4-0.5 permil for δ\delta18O values and 1.1-1.9 permil for δ\delta2H values for water amounts of 0.1-0.5 μ\mul, which improves with increasing water amount to 0.1-0.3 permil and 0.2-0.7 permil, respectively, above 1 μ\mul. The accuracy of measurements of water injections and water-filled glass capillaries crushed in the system is better than 0.08 permil for δ\delta18O and 0.3 permil for δ\delta2H values. The reproducibility (1σ\sigma) based on replicate analysis of speleothem fluid inclusion samples with water amounts > 0.2 μ\mul is 0.5 permil for δ\delta18O and 1.2 permil for δ\delta2H values, respectively. Isotopic differences between the water vapour background of the extraction system and the fluid inclusions have no significant impact on the measured fluid inclusion isotope values if they are within 10 permil for δ\delta18O and 50 permil for δ\delta2H values of the background. Tests of potential adsorption effects with inclusion free spar calcite confirm that the isotope values are unaffected by adsorption for water contents of about 1 μ\mul (fluid inclusion) water per g of carbonate or above. Fluid inclusion analysis on three different modern to late Holocene speleothems from caves in northwest Germany resulted ...

Keywords

Cite

@article{arxiv.2301.01493,
  title  = {Constraints for precise and accurate fluid inclusion stable isotope analysis using water-vapour saturated CRDS techniques},
  author = {Therese Weissbach and Tobias Kluge and Stéphane Affolter and Markus C. Leuenberger and Hubert Vonhof and Dana F. C. Riechelmann and Jens Fohlmeister and Marie-Christin Juhl and Benedikt Hemmer and Yao Wu and Sophie F. Warken and Martina Schmidt and Norbert Frank and Werner Aeschbach},
  journal= {arXiv preprint arXiv:2301.01493},
  year   = {2023}
}