English

Comment on "Nuclear Emissions During Self-Nucleated Acoustic Cavitation"

General Physics 2009-11-11 v2 Nuclear Experiment Nuclear Theory

Abstract

In a recent Letter to PRL, Taleyarkhan and coauthors claim to observe DD fusion produced by acoustic cavitation. Among other evidence, they provide a proton recoil spectrum that they interpret as arising from 2.45 MeV DD fusion neutrons. My analysis concludes the spectrum is inconsistent with 2.45 MeV neutrons, cosmic background, or a PuBe source, but it is consistent with a Cf-252 source.

Cite

@article{arxiv.physics/0603060,
  title  = {Comment on "Nuclear Emissions During Self-Nucleated Acoustic Cavitation"},
  author = {B. Naranjo},
  journal= {arXiv preprint arXiv:physics/0603060},
  year   = {2009}
}

Comments

1 page, 1 figure, comment regarding Taleyarkhan et al., PRL 96 034301 (2006), revised and added supplemental methods (physics/0609083), accepted for publication in PRL