Abstract

ARIADNE is a nuclear-magnetic-resonance-based experiment that will search for novel axion-induced spin-dependent interactions between an unpolarized source mass rotor and a nearby sample of spin-polarized 3^3He gas. To detect feeble axion signals at the sub-atto-Tesla level, the experiment relies on low magnetic background and noise. We measure and characterize the magnetic field background from a prototype tungsten rotor. We show that the requirement is met with our current level of tungsten purity and demagnetization process. We further show that the noise is dominantly caused by a few discrete dipoles, likely due to a few impurities trapped inside the rotor during manufacturing. This is done via a numerical optimization pipeline which fits for the locations and magnetic moments of each dipole. We find that under the current demagnetization, the magnetic moment of trapped impurities is bounded at 109Am210^{-9} \mathrm{A}\mathrm{m}^2.

Keywords

Cite

@article{arxiv.2011.12617,
  title  = {Characterization of magnetic field noise in the ARIADNE source mass rotor},
  author = {Nancy Aggarwal and Allard Schnabel and Jens Voigt and Alex Brown and Josh C Long and L. Trahms and A. Fang and Andrew Geraci and A. Kapitulnik and D. Kim and Y. Kim and I. Lee and Y. H. Lee and C. Y. Liu and C. Lohmeyer and A. Reid and Y. Semertzidis and Y. Shin and J. Shortino and E. Smith and W. M. Snow and E. Weisman},
  journal= {arXiv preprint arXiv:2011.12617},
  year   = {2020}
}

Comments

6 pages, 5 figures