English

Automatic segmentation and determining radiodensity of the liver in a large-scale CT database

Image and Video Processing 2020-01-01 v1 Computer Vision and Pattern Recognition Medical Physics

Abstract

This study proposes an automatic technique for liver segmentation in computed tomography (CT) images. Localization of the liver volume is based on the correlation with an optimized set of liver templates developed by the authors that allows clear geometric interpretation. Radiodensity values are calculated based on the boundaries of the segmented liver, which allows identifying liver abnormalities. The performance of the technique was evaluated on 700 CT images from dataset of the Unified Radiological Information System (URIS) of Moscow. Despite the decrease in accuracy, the technique is applicable to CT volumes with a partially visible region of the liver. The technique can be used to process CT images obtained in various patient positions in a wide range of exposition parameters. It is capable in dealing with low dose CT scans in real large-scale medical database with over 1 million of studies.

Keywords

Cite

@article{arxiv.1912.13290,
  title  = {Automatic segmentation and determining radiodensity of the liver in a large-scale CT database},
  author = {N. S. Kulberg and A. B. Elizarov and V. P. Novik and V. A. Gombolevsky and A. P. Gonchar and A. L. Alliua and V. Yu. Bosin and A. V. Vladzymyrsky and S. P. Morozov},
  journal= {arXiv preprint arXiv:1912.13290},
  year   = {2020}
}

Comments

16 pages, 8 figures