Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values
Abstract
The technique of almost-balanced weak values amplification (ABWV) was recently proposed [Phys. Rev. Lett. 116: 100803 (2016)]. We demonstrate this technique using a modified Sagnac interferometer, where the counter-propagating beams are spatially separated. The separation between the two beams provides additional amplification, with respect to using colinear beams in a Sagnac interferometer. As a demonstration of the technique, we perform measurements of the angular velocity in one of the mirrors of the interferometer. Within the same setup, the weak-value amplification technique is also performed for comparison. Much higher amplification factors can be obtained using the almost-balanced weak values technique, with the best one achieved in our experiments being as high as . In addition, the amplification factor monotonically increases with decreasing post-selection phase for the ABWV case in our experiments, which is not the case for weak-value amplification at small post-selection phases.
Keywords
Cite
@article{arxiv.1612.08314,
title = {Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values},
author = {Wei-Tao Liu and Julián Martínez-Rincón and Gerardo I. Viza and John C. Howell},
journal= {arXiv preprint arXiv:1612.08314},
year = {2017}
}
Comments
4 pages, 3 figures. comments are welcome